Production Hardware Guide

This page provides hardware sizing and configuration guidance for production RustFS deployments.

Planning Considerations

Before deploying RustFS in production, assess your workload and capacity requirements over a two- to three-week period. Focus on the following factors:

  1. Data volume
  • Initial data volume: Estimate the usable data volume at go-live (in TiB), including the ratio of hot to cold data.
  • Growth forecast: Estimate data growth for the next 24 months based on business plans. We recommend modeling growth quarterly.
  • Object count: Estimate the total number of objects from the average object size (ideally 128 KB to 1 MB). Deployments with more than 100 million objects need additional tuning.
  1. Workload characteristics
  • Access Patterns: Distinguish read-intensive (such as content distribution) from write-intensive (such as log collection) scenarios
  • Compliance requirements: Retention periods must meet industry regulations (for example, some financial regulations require at least five years of retention).
  • Multi-site deployment: For cross-region deployments, assess network latency (ideally under 50 ms) and bandwidth costs.
  1. Storage Architecture Design
  • Bucket planning: Organize buckets by business unit. We recommend no more than 500 active buckets per cluster.
  • Disaster recovery: Choose active-active replication (recommended) or asynchronous replication based on how critical the data is.

Hardware Configuration Matrix

Baseline configurations based on load-test results:

ComponentEntry levelStandard productionHigh performance
Node Count4 nodes8 nodes16+ nodes
Storage Media4× NVMe SSD8×NVMe SSD12×NVMe SSD
Network ArchitectureDual 25GbE (link aggregation)Dual 100GbE200GbE
CPU2×Intel Silver 4310 (16 cores)2×AMD EPYC 7313 (32 cores)2×Intel Platinum 8461Y (48 cores)
Memory64 GB DDR4-3200 ECC256 GB DDR5-4800 ECC512 GB DDR5-5600 ECC
Storage ControllerHBA 9500-8iHBA 9600-16iDual controller redundant architecture

Deployment guidelines:

  1. Use homogeneous nodes: every node should have identical hardware from the same batch and the same firmware versions.
  2. The network must use a leaf-spine topology, a physically isolated storage network, and dual uplinks.
  3. We recommend 2U servers with at least 12 drive bays per node, depending on the number of drives required.

Performance tuning

Network Topology Optimization (Highest Priority)

  • Bandwidth sizing: Provision 0.5 Gbps of bandwidth per TB of usable data (for example, 100 TB of data needs 50 Gbps of dedicated bandwidth).
  • Latency Requirements:
  • Inter-node P99 latency ≤ 2ms
  • Cross-rack latency ≤ 5ms

Storage Subsystem Tuning

  • Controller Configuration:
  • Enable read-ahead cache (recommended 256 MB+)
  • Disable all RAID features and use pass-through (HBA/JBOD) mode.
  • Check BBU health regularly
  • SSD Parameters:
  • Reserve 20% over-provisioning (OP) space to improve endurance
  • Enable atomic writes (requires hardware support)

Memory allocation

  • Allocation Ratios:
  • Metadata cache: 60% of total memory
  • Read/write buffers: 30%
  • System reserve: 10%

Network Design Reference Model

Network bandwidth vs. disk count

NetworkTheoretical throughputDisk typeMax disks per node
10GbE1.25 GB/s7.2K HDD (180 MB/s)8 disks
25GbE3.125 GB/sSATA SSD (550 MB/s)6 disks
100GbE12.5 GB/sNVMe Gen4 (7 GB/s)2 (at full read/write speed)

Example: A video platform runs a 16-node cluster. Each node has:

  • 8×7.68 TB NVMe SSD
  • Dual 100GbE NVIDIA ConnectX-5 NICs
  • Achieves aggregate throughput of 38 GB/s

Memory sizing

Use the following formula to size memory based on disk capacity and workload type:

# Memory calculation formula (unit: GB)
def calc_memory(data_tb, access_pattern):
 base = 32 # Base memory
 if access_pattern == "read_heavy":
 return base + data_tb * 0.8
 elif access_pattern == "write_heavy":
 return base + data_tb * 1.2
 else: # mixed
 return base + data_tb * 1.0

Reference sizes:

Data sizeRead-heavyWrite-heavyMixed
10 TB40 GB44 GB42 GB
100 TB112 GB152 GB132 GB
500 TB432 GB632 GB532 GB

Storage guidelines

Choosing storage media

MetricHDDSATA SSDNVMe (required)
Latency Requirements>50ms1 to 10ms< 1ms
Throughput Requirements< 500 MB/s500 MB-3 GB/s> 3 GB/s
Typical use casesArchival storageHot-data cacheReal-time analytics

File System Configuration

# XFS formatting example
mkfs.xfs -f -L rustfs_disk1 -d su=256k,sw=10 /dev/sdb

# Recommended mount parameters
UUID=xxxx /mnt/disk1 xfs defaults,noatime,nodiratime,logbsize=256k 0 0

High availability

  1. Power Supply:
  • Use dual (redundant) power supplies
  • Connect each PDU to a separate power feed
  • Provide a UPS with at least 30 minutes of runtime.
  1. Cooling Requirements:
  • Rack power density ≤ 15 kW per rack
  • Keep the inlet-to-outlet temperature difference (ΔT) within 8 °C
  1. Firmware Management:
  • Maintain a hardware compatibility matrix
  • Standardize on the same firmware versions across nodes

Before go-live

We recommend running a 72-hour stress test before production go-live that covers the following scenarios:

  1. Node failover tests
  2. Network partition tests
  3. Burst write load tests (we recommend testing at 120% of the theoretical maximum)

This guide is based on the latest RustFS development version. For production deployments, fine-tune these settings using your hardware vendor's documentation. For quarterly hardware health assessments, contact RustFS.